Services

Data Center Tenant Handback

Before-and-after laser scanning and an asset register that reconciles move-out against the signed handback schedule.

When a tenant leaves a data center, the owner needs to know exactly what was left behind, what was taken out, and whether the space was returned in the condition both parties agreed to. We document the facility before and after move-out and check what we find in the field against the owner and tenant's signed handback schedule.

The work is set up for the building owner and the MEP design team. Every asset gets one record that follows it through both visits, so each item on the schedule ends with a clear finding.

MEP point cloud showing mechanical, electrical, and plumbing systems: Laser Scan Chicago
Point cloud of mechanical, electrical, and plumbing systems captured with laser scanning.

How It Works

1. Before move-out: baseline scan and inventory

We agree with you on the rooms, asset classes, access windows, and what may be photographed. Then we scan the agreed areas and inventory each in-scope asset by ID, location, visible condition, and the nameplate data we can reach. Approved photos are linked to the register, and any inaccessible item or unreadable tag is listed as such.

2. Before removal: the agreed handback schedule

We issue the baseline register so the owner and tenant can mark each item for retention, removal, or replacement. The register records the required condition and any area restoration or test evidence that is due. The parties approve a dated schedule, and any later agreed revisions are tracked against it.

3. After move-out: verification visit

We rescan the same areas in the same coordinate system and check every schedule entry against its ID, location, and observed condition. The result shows what stayed, what was removed, and where the field differs from the signed handback list. Access limitations and evidence still outstanding are recorded, and functional test results supplied by the MEP or commissioning team are referenced.

Registered laser scan point cloud of a building and site: Laser Scan Chicago
Registered point cloud. Both visits are captured in one coordinate system so each asset can be compared in place.

What We Record for Each Asset

  • Identity: room, equipment type, visible asset tag, and manufacturer, model, and serial number where legible. If the field tag differs from the owner's equipment register, both identifiers are kept.
  • Location: the scan location and the permitted photographs for that item.
  • Agreed outcome: the disposition, required condition, the approved schedule revision it comes from, and the evidence requested for handback.
  • Observed outcome: what the survey team actually saw. Owner or tenant instructions are recorded separately from field observations.

Unobserved Is Not the Same as Removed

Restricted areas, obscured nameplates, and equipment that cannot be safely observed are identified up front. We document the extent of capture at each visit, so the review team can tell an item we could not see apart from a confirmed removal.

Exceptions, Reported Separately

For every variance we give the location, the agreed outcome, the field finding, and a supporting photo or scan view. Separate findings stay separate: if a pump was removed as agreed but the specified housekeeping pad repair is still incomplete, the removal and the outstanding repair are reported as two items.

Deliverables

  • Registered before-and-after point clouds (RCP/RCS)
  • An editable asset register showing required and observed outcomes, ready for the owner and MEP team to add comments and closeout decisions
  • A PDF exception report with paired before-and-after views or photos

Each entry is marked verified as agreed, variance, or pending verification. Where testing is required and the evidence is not yet in, functional condition is marked pending, and test reports are referenced by document ID when supplied. The owner makes the acceptance decision; we identify any follow-up observations needed to support it.

If the design team also needs a Revit model, it can be priced separately and produced from the same scan data.

Requesting a Fee Proposal

To price a handback project, send us what you have of the following:

  • Floor plans
  • Approximate area and asset count
  • Available equipment records
  • Site access and data-handling requirements
  • Both visit dates (before and after move-out)

Request a quote or contact us to talk through the scope.

Common Questions

Data Center Handback FAQ

Who is this service for?

Building owners and their MEP design teams who need an independent record of a tenant's move-out, checked against the signed handback schedule.

Do you perform functional testing of equipment?

No. We reference functional test results supplied by the MEP or commissioning team. Where testing is required and the evidence is outstanding, the item is marked pending.

Who decides whether the space is accepted?

The owner. We report each item as verified as agreed, variance, or pending verification, and identify any follow-up observations needed for the owner's decision.

What if an item could not be seen during a visit?

It is recorded as not observed, with the reason, and the extent of capture is documented for each visit. An item we could not see is never reported as removed.

Can you work within our site security and data rules?

Yes. Access windows, permitted photography, and data-handling requirements are agreed before mobilization and are part of the fee proposal.